+44 (0) 800 123 4567 No.1 Abbey Road London, W1 ECH, UK
  • ZYGLO ZA-28 Modular System

ZYGLO ZA-28 Modular System

Each of the three ZA-28 models is designed for a specific testing method. Since the order of use varies with different penetrant materials, the units must be carefully ordered to fit your application.

ZA-28W for Water Washable Method : This is the simplest unit because water can be used directly to wash excess penetrant from parts without additional steps.

ZA-28E for Post-Emulsified Method : This unit can locate extremely shallow flaws, but it requires an extra processing step applying an emulsifier to make penetrant washable.

ZA-28H for Hydrophilic Method : This unit delivers the highest inspection sensitivity, but it requires an additional processing station for pre-rinsing parts.

The accompanying chart shows the work flow for each model:

ZA-28W WATER WASHABLE METHOD:

- Penetrant Tank
- Rinse Tank
- Drier
- Dry Developer
- Inspection Booth

ZA-28E POST EMULSIFIER METHOD (OIL BASED):

- Emulsifier Tank
- Penetrant Tank
- Rinse Tank
- Drier
- Dry Developer
- Inspection Booth

ZA-28H POST EMULSIFIER METHOD (WATER BASED):

- Penetrant Tank
- Rinse Tank
- Emulsifier Tank
- Rinse Tank
- Drier
- Dry Developer
- Inspection Booth

Tank sizes 400 x 400 x 850 mm